Saturday, August 22, 2020

Analysis and Design of Cable Stayed Bridge Essays

Examination and Design of Cable Stayed Bridge Essays Investigation and Design of Cable Stayed Bridge Essay Investigation and Design of Cable Stayed Bridge Essay Of the recently assembled Bridgess, link stayed Bridgess are today extremely regular worldwide for ranges runing somewhere in the range of 200 and 900 meters. An abroad message stayed length has at least one towers ( Pylons ) from which the abroad wires bolster the deck. This paper gives demonstrating, investigation and plan of a prestressed harp type singular arch abroad message stayed length using MIDAS Civil. Watchwords: abroad wire stayed, box support, prestressing, MIDAS Civil Introduction Of the recently manufactured Bridgess, link stayed Bridgess are today extremely normal worldwide for ranges runing somewhere in the range of 200 and 900 meters. An abroad message stayed range has at least one towers ( Pylons ) from which the abroad wires bolster the deck. There are two significant classes of link stayed Bridgess: harp and fan.In the harp structure, the abroad messages are about equal with the goal that the stature of their affectionate respect to the pinnacle is like the good ways from the pinnacle to their get on the deck.In the fan plan, the abroad wires all associate with or base on balls over the highest point of the towers. The link stayed range is ideal for ranges longer than cantilever Bridgess, and shorter than suspension Bridgess. This is the extension where cantilever Bridgess would rapidly go heavier if the range was extended, and suspension length transmitting would non be progressively affordable if the range was abbreviated Cable-stayed Bridgess may seem to be like suspension Bridgess, yet in reality they are somewhat extraordinary in rule and in their structure. In suspension Bridgess, huge boss abroad messages ( typically 2 ) twisted between the towers ( normally 2 ) , and are moored at every terminal to the land though in the link stayed range, the towers are the essential supporting developments which transmitt the range burdens to the land. A cantilever assault is habitually used to back up the range deck close to the towers, however lengths farther from them are bolstered by abroad messages running directly to the towers. General introduction of the development The range is an individual arch abroad wire stayed length holding a harp-type understanding of the abroad wires. The whole length of the abroad wire stayed range is 700m with a central range of 350m. The range development conveys 6 course paths separated into 2 carriageways. The deck comprises of performers in topographic point prestressed box braces Whole broadness of the range is 29.8m. Development technique The boss 350 m length will be fabricated using the cantilever technique, get bringing down from the wharfs P4 A ; P5 simultaneously. The two cantilevers will be associated at mid range by the mean of a line area. The fair cantilevers are thrown by segments of 3.5 m long, using a signifier voyager. The segment ( n ) is associated with old area ( n-1 ) by ligaments ( interior pre-focusing on ) . This technique is utilized for the initial 10 segments from arch. After eleventh segment, no cantilever ligament is required as the segments will be upheld by remain abroad messages tensioned progressively with working of segments. Consequently fabricating cadence of segments after eleventh one incorporates introducing and tensioning of remain abroad wire before remotion and propelling of signifier voyager. Material highlights: Concrete: M50 grade solid will be utilized for deck and arches. M50 grade solid will be utilized for Piers. Concrete belongingss will be founded on AASHTO LRFD Bridge Design Specifications. Youthful modulus according to IRC codification is given in the accompanying plain exhibit ( IRC:21  § 303.1. ) : Shear modulus of solid, G, is determined using the undermentioned condition: E= Ec/2 ( 1+? ) The coefficient of thermic broadening and compression for typical weight concrete is taken as 1.17?10-5/ °C. Thickness of the pre-focused on concrete is taken equivalent to 25 KN/m3. Steel support: Thermo-precisely rewarded help bars of class 414 fitting in with IS:1786 will be received. Yielding quality of dormant steel support is viewed as equivalent to 414 MPa and Young modulus equivalent to 200 000 Mpa. Measured proportion among cement and steel will be taken equivalent to 10. Dead tonss: oneself weight is determined assuming a thickness of 25 KN/m3 for strengthened and prestressed concrete. A thickness of 7.85 t/m3 is to be considered for steel. Live Tonss: Traffic live loads-The unrecorded tonss are in similarity with IRC:6-2000. The range has two carriageways of three paths each and of 11 m broadness. Every carriageway will be stacked with three paths of IRC classification A weight. Person on foot unrecorded weight ( PLL ) The pes way replenishing will be according to proviso 209 of IRC:6 with quality of filling equivalent to 500 kg/m? . Wind trouble for abroad wire stayed length: Harmonizing to IS:875 ( parcel 3 ) - 1987 Wind stacks on unrecorded tonss ( WL ) The sidelong air current power against voyaging unrecorded tonss will be considered as moving at 1.5 m over the roadway and will be expected equivalent to 300 kg/m. Creep and Shrinkage ( C A ; S ) Creep and contracting impacts to be considered according to CEB-FIP codification for abroad message stayed range Earthquake tonss Rajasthan is situated in seismal zone II. The flat seismal coefficient in longitudinal manner will be determined by IS 1893:2002 Construction tonss: Normal opposite burdens A structure weight of 50 kg/m2 will be considered during cantilever hard-on. Weight of the voyager signifier is thought to be equivalent to 85 dozenss. An effect of 10 % will be considered for the voyaging building tonss. MIDAS MODEL of box: ( Half range ) AASHTO LRFD Bridge Design Specifications ( Third Edition, 2005 Interim Revisions ) ; AASHTO †Guide Specifications for Seismic Isolation Design ( second release †2000 ) ; AASHTO †Guide Specifications for Design A ; Construction of Segmental Concrete Bridges ( 1999 ) ; IRC:6-2000 Standard Specifications A ; Code of Practice for Road Bridges, Section II, Loads A ; emphasiss ( fourth version †2000 ) ; for meaning of the unrecorded tonss and quake tonss just ; IS:875 ( divide 3 ) - 1987 Code of example for plan tonss ( other than earthquake ) for buildings and developments ; for air current loads only ; Necessities of Bridge innovation by D.Johnson Victor Extension Engineering Handbook Edited by Wai-Fah Chen, Lian Duan, CRC Press

No comments:

Post a Comment

Note: Only a member of this blog may post a comment.